Request
19
Response
20
Set
optional
Position in BX
11

This command takes the opposite direction of the others: The device does not ask, it reports. It sends item details it has determined itself – the weight from the scale of a sorter, say, or the identifier of a newly fitted RFID label – so that the library system can keep them.

Nothing is booked. Neither checkout nor check-in is affected.

Request 19#

19<timestamp><AO...><AB...><AC...><CH...>
Field Length Required Content
timestamp 18 yes date and time on the device
Identifier Required Content
AO yes institution identifier
AB yes item identifier
AC no terminal password
CH yes item properties

Response 20#

20<item properties ok><timestamp><AB...><AJ...><CH...><AF...><AG...>
Field Length Required Content
item properties ok 1 yes 1 stored, 0 not stored
timestamp 18 yes date and time on the library system
Identifier Required Content
AB yes item identifier from the request
AJ no short title
CH no item properties as now stored
AF no message for the screen
AG no message for the receipt

A library system that does not store the properties answers 0. That is not an error but a factual statement: The message arrived and was not adopted.

Example#

1920260728    143012AOBVS|AB1140360000123|CH350g|AY2AZF368<CR>
20120260728    143012AB1140360000123|AY2AZF73C<CR>